1989 Ford F-250 Custom 4.9L Battery
Customer came in with complaint of charging system not maintaining battery charge. Altenator maintains charge under light to moderate load (14.0 Volts). With headlights on & A/C blower on high system can not maintain voltage. Altenator putting out 80 Amps....
FIX posted 3/18/2000