1991 Ford Mustang LX 5.0L No Start, Cuts out, Stall
Hi everyone and thanks for reading this I have my customers ranger with a 1991 mustang engine and fuel injection (multi port) it will start but dies right away, when I checked the ect circuit I only have .5 volts with sensor unpluged when I unplug the maf (it ...
FIX posted 8/2/2005
iATN Members:
Login to view full TechHelp request Auto Repair Pros: Join iATN to read this TechHelp request Vehicle Owners: Find a nearby iATN member to repair your vehicle 3 Replies Received (View Replies)3 Replies Received (Hide Replies)
|
Message Closed w/FIX
|
| VIN | [No VIN Available] |
| Engine | 5.0 L / 8 cyl / GAS |
| Trans | 4-speed Automatic |
| Delivery | FI |
| Symptoms | No Start, Cuts Out, Stall |
| Occurs | Always |
| Misc. | Ranger Conversion |
Trouble Codes
| 24 | air charge temp |
| 61 | coolant temp |
Message Closed w/FIX
Vehicle Data
1991 Ford Mustang LX
| VIN | [No VIN Available] |
| Engine | 5.0 L / 8 cyl / GAS |
| Trans | 4-speed Automatic |
| Delivery | FI |
| Symptoms | No Start, Cuts Out, Stall |
| Occurs | Always |
| Misc. | Ranger Conversion |
Trouble Codes
| 24 | air charge temp |
| 61 | coolant temp |
3 Replies Received
3 Replies Received