1998 Volvo S70 2.4L MIL Lamp on
Hi all! I've got an volvo here setting a code for air injection failure (P0410). Checked system and found that ecm is not grounding the pump or the solenoid. Control valve and pump are working. Valve is seeping alittle when closed. I'm familiar with the proble...
FIX posted 2/10/2004
iATN Members:
Login to view full TechHelp request Auto Repair Pros: Join iATN to read this TechHelp request Vehicle Owners: Find a nearby iATN member to repair your vehicle 5 Replies Received (View Replies)5 Replies Received (Hide Replies)
|
Message Closed w/FIX
|
| VIN | YV1LS5574W |
| Engine | 2.4 L / 5 cyl / GAS |
| Trans | 4-speed Automatic (Electronic) |
| Delivery | FI |
| Emissions | OBD-II Compliant |
| Symptoms | MIL Lamp On |
| Occurs | Always |
Trouble Codes
| P0410 | AIR System Oxygen Sensor Monitor |
Message Closed w/FIX
Vehicle Data
1998 Volvo S70
| VIN | YV1LS5574W |
| Engine | 2.4 L / 5 cyl / GAS |
| Trans | 4-speed Automatic (Electronic) |
| Delivery | FI |
| Emissions | OBD-II Compliant |
| Symptoms | MIL Lamp On |
| Occurs | Always |
Trouble Codes
| P0410 | AIR System Oxygen Sensor Monitor |