1997 Other European 355 spider 3.5L MIL Lamp on
Replaced both o2 sensors on bank 2. Checked mixture before
and after CAT (OK) Smoke tested for any vaccum leaks, none
found. Checked voltages at all O2 sensors. ok. Back
pressure ckecked out .ok.
FIX posted 5/10/2001
iATN Members:
Login to view full TechHelp request Auto Repair Pros: Join iATN to read this TechHelp request Vehicle Owners: Find a nearby iATN member to repair your vehicle |
Message Closed w/FIX
|
| VIN | [No VIN Available] |
| Engine | 3.5 L / 8 cyl |
| Delivery | FI |
| Emissions | OBD-II Compliant |
| Symptoms | MIL Lamp On |
| Occurs | Cruise |
Trouble Codes
| P0154 | Air Fuel Sensor (Bank 2 Sensor 1) Heater Circuit Malfunction |
Message Closed w/FIX
Vehicle Data
1997 Ferrari 355 spider
| VIN | [No VIN Available] |
| Engine | 3.5 L / 8 cyl |
| Delivery | FI |
| Emissions | OBD-II Compliant |
| Symptoms | MIL Lamp On |
| Occurs | Cruise |
Trouble Codes
| P0154 | Air Fuel Sensor (Bank 2 Sensor 1) Heater Circuit Malfunction |