		when the engine reaches between 205-210 degrees the fan gets a pwm signal (8.8 duty cycle according to modis scope) and runs full speed. cycles on and off always on high. runs on high speed with the ac on. vac bleed the cooling system, driven over 20 miles... 
                        
                            FIX posted 7/20/2020
                             
                 
                            
                    iATN Members:  
        Login to view full TechHelp request Auto Repair Pros: Join iATN to read this TechHelp request Vehicle Owners: Find a nearby iATN member to repair your vehicle 6 Replies Received (View Replies)6 Replies Received (Hide Replies)
       | 
		  
		      
           Message Closed w/FIX 
	   
	   
	   
	    | 
| VIN | 1C4RDHAG2D | 
| Engine | 3.6 L / 6 cyl / FLEX | 
| Trans | 5-speed Automatic (Electronic) | 
| Delivery | Fuel Injection | 
| Affected | Cooling Fan | 
| Conditions | Runs on High | 
Message Closed w/FIX
            
            