1998 Chrysler Sebring LX 2.5L No Start, No Crank
I have this vehicle that does not crank over. I found the starter motor relay is not receiving a signal from the PCM to trigger the relay at circuit K90. All others at the relay are ok. I checked the p/n swicth sense (ckt T41) circuit and it's being grounded a...
FIX posted 12/9/2003
iATN Members:
Login to view full TechHelp request Auto Repair Pros: Join iATN to read this TechHelp request Vehicle Owners: Find a nearby iATN member to repair your vehicle 8 Replies Received (View Replies)8 Replies Received (Hide Replies)
|
Message Closed w/FIX
|
| VIN | 3G3EL55HXW |
| Engine | 2.5 L / 6 cyl / GAS |
| Trans | 4-speed Automatic (Electronic) |
| Delivery | FI / SEFI |
| Emissions | OBD-II Compliant |
| Symptoms | No Start, No Crank |
| Occurs | Always |
| Misc. | Sebring Jxi Convertible |
Message Closed w/FIX
Vehicle Data
1998 Chrysler Sebring LX
| VIN | 3G3EL55HXW |
| Engine | 2.5 L / 6 cyl / GAS |
| Trans | 4-speed Automatic (Electronic) |
| Delivery | FI / SEFI |
| Emissions | OBD-II Compliant |
| Symptoms | No Start, No Crank |
| Occurs | Always |
| Misc. | Sebring Jxi Convertible |
8 Replies Received
8 Replies Received
Related Documents & Media