1995 Plymouth Grand Voyager SE 3.0L MIL Lamp on
I have a Plymouth Grand Voyager with an o2 sensor code #21 for o2 sensor not switching rich or lean but stays in the middle. The o2 sensor signal is perfectly balanced and then it just goes to a fixed value .49 to .53 volts and sets the code 21, after its been...
FIX posted 12/5/2002
iATN Members:
Login to view full TechHelp request Auto Repair Pros: Join iATN to read this TechHelp request Vehicle Owners: Find a nearby iATN member to repair your vehicle 10 Replies Received (View Replies)10 Replies Received (Hide Replies)
|
Message Closed w/FIX
|
| VIN | JP4GH4532S |
| Engine | 3.0 L / 6 cyl / GAS |
| Trans | 4-speed Automatic (Electronic) |
| Delivery | FI / SEFI |
| Emissions | Not OBD-II Compliant |
| Symptoms | MIL Lamp On |
| Occurs | Cold, Hot, Intermittently |
Trouble Codes
| 21 | o2 sensor fixed in the middle |
Message Closed w/FIX
Vehicle Data
1995 Plymouth Grand Voyager SE
| VIN | JP4GH4532S |
| Engine | 3.0 L / 6 cyl / GAS |
| Trans | 4-speed Automatic (Electronic) |
| Delivery | FI / SEFI |
| Emissions | Not OBD-II Compliant |
| Symptoms | MIL Lamp On |
| Occurs | Cold, Hot, Intermittently |
Trouble Codes
| 21 | o2 sensor fixed in the middle |