	 2000 Honda Accord SE 2.3L MIL Lamp on 
		
		The problem I am having on this Honda is with the upstream O2 sensor. On a lab scope, the sensor signal is fixed at 2.5 volts. If the sensor is disconnected, on the harness side, the signal wire has 2.5 volts (Coming from the PCM, to the sensor). So does the o... 
                        
                            FIX posted 2/15/2017
                             
                 
                            
                    iATN Members:  
        Login to view full TechHelp request Auto Repair Pros: Join iATN to read this TechHelp request Vehicle Owners: Find a nearby iATN member to repair your vehicle 18 Replies Received (View Replies)18 Replies Received (Hide Replies)
       | 
		  
		      
           Message Closed w/FIX 
	   
	   
	   
	    | 
| VIN | JHMCG6690Y | 
| Engine | 2.3 L / 4 cyl / GAS | 
| Trans | 4-speed Automatic (Electronic) | 
| Delivery | Fuel Injection / sefi | 
| Emissions | OBD-II Compliant | 
| Symptoms | MIL Lamp On | 
| Occurs | Always | 
Trouble Codes
| P0420 | Catalyst Efficiency Below Threshold (Bank 1) | 
Message Closed w/FIX
            
            
 Vehicle Data
                2000 Honda Accord SE
| VIN | JHMCG6690Y | 
| Engine | 2.3 L / 4 cyl / GAS | 
| Trans | 4-speed Automatic (Electronic) | 
| Delivery | Fuel Injection / sefi | 
| Emissions | OBD-II Compliant | 
| Symptoms | MIL Lamp On | 
| Occurs | Always | 
Trouble Codes
| P0420 | Catalyst Efficiency Below Threshold (Bank 1) | 
                            