2001 Infiniti QX4 3.5L MIL Lamp on
Vehicle was brought to other shop for emissions p0301 and p1320. Replaced coil on cyl 1, no misfire, engine runs smooth, p1320 comes back immediately after clearing. Shop replaced both crank sensors. Alldata info stated that logic of code is when primary ignit...
FIX posted 1/23/2014
iATN Members:
Login to view full TechHelp request Auto Repair Pros: Join iATN to read this TechHelp request Vehicle Owners: Find a nearby iATN member to repair your vehicle 8 Replies Received (View Replies)8 Replies Received (Hide Replies)
|
Message Closed w/FIX
|
| VIN | JNRDR07Y31 |
| Engine | 3.5 L / 6 cyl / GAS |
| Trans | 4-speed Automatic (Electronic) |
| Delivery | Fuel Injection |
| Emissions | OBD-II Compliant |
| Symptoms | MIL Lamp On |
| Occurs | Always |
Trouble Codes
| P1320 | ICM 4X Reference Circuit No Pulses (Intermittent) |
Message Closed w/FIX
Vehicle Data
2001 Infiniti QX4
| VIN | JNRDR07Y31 |
| Engine | 3.5 L / 6 cyl / GAS |
| Trans | 4-speed Automatic (Electronic) |
| Delivery | Fuel Injection |
| Emissions | OBD-II Compliant |
| Symptoms | MIL Lamp On |
| Occurs | Always |
Trouble Codes
| P1320 | ICM 4X Reference Circuit No Pulses (Intermittent) |
8 Replies Received
8 Replies Received