International Automotive Technicians Network
Slow cranking starter waveform
Posted to the Waveform Library on 1/7/2018

Amperage waveform from a slow cranking Cat C7 engine. Of note: 900A peak inrush, sizeable solenoid contact bounce, 480A average.