MSD Digital 7 CD ignition at idle, multistrike, current over KV 1 strike
Posted to the Waveform Library on 10/20/2003

Channel 1 trace is 1 strike at idle, showing about 8kv. Channel 2 is from a Fluke current probe set at 100mv/Amp. This shows 500mv per division, or 5 amps per division. The current ramp is 24 amps for that firing. Burn time appears to be 55us.