2001 Cadillac DeVille 4.6L No Start
This car came in for check over after the purchase of this car. It had many codes for misfire, TCC, Secondary air pump, crank and cam codes and PCM memory. The battery died over night and I charged it up in the morning and did a compression test and injector d...
FIX posted 8/12/2014
![]()
iATN Members:
Login to view full TechHelp request Auto Repair Pros: Join iATN to read this TechHelp request Vehicle Owners: Find a nearby iATN member to repair your vehicle (View Replies)6 Replies Received(Hide Replies)6 Replies Received
|
Message Closed w/FIX
|
VIN | 1G6KD54YX1 |
Engine | 4.6 L / 8 cyl / GAS |
Trans | 4-speed Automatic (Electronic) |
Delivery | Fuel Injection |
Emissions | OBD-II Compliant |
Symptoms | No Start |
Trouble Codes
P0300 | Multiple Misfire Detected |
P0335 | Crankshaft Position Sensor 1 Circuit Malfunction (No Signal) |
P0340 | Camshaft Position Sensor 'A' (TDC) Circuit Intermittent |
P0385 | Camshaft Position Sensor 'B' Circuit Malfunction |
P0410 | AIR System Oxygen Sensor Monitor |
Message Closed w/FIX
Vehicle Data
2001 Cadillac DeVille
VIN | 1G6KD54YX1 |
Engine | 4.6 L / 8 cyl / GAS |
Trans | 4-speed Automatic (Electronic) |
Delivery | Fuel Injection |
Emissions | OBD-II Compliant |
Symptoms | No Start |
Trouble Codes
P0300 | Multiple Misfire Detected |
P0335 | Crankshaft Position Sensor 1 Circuit Malfunction (No Signal) |
P0340 | Camshaft Position Sensor 'A' (TDC) Circuit Intermittent |
P0385 | Camshaft Position Sensor 'B' Circuit Malfunction |
P0410 | AIR System Oxygen Sensor Monitor |