Replaced downstream O2 sensor on passenger side (Bank 2, Sensor 2), cleared the code. MIL & same code came back 35 miles later. My scanner is showing very LOW voltage output from the new sensor. How can I test the output voltage of the new sensor?
FIX posted 11/24/2008
![]()
iATN Members:
Login to view full TechHelp request Auto Repair Pros: Join iATN to read this TechHelp request Vehicle Owners: Find a nearby iATN member to repair your vehicle (View Replies)16 Replies Received(Hide Replies)16 Replies Received
|
Message Closed w/FIX
|
VIN | 3GNEC16T21 |
Engine | 5.3 L / 8 cyl / GAS |
Trans | 4-speed Automatic (Electronic) |
Delivery | FI |
Emissions | OBD-II Compliant |
Symptoms | MIL Lamp On |
Occurs | Always |
Trouble Codes
P0157 | Heated Oxygen Sensor (Bank 2 Sensor 2) Circuit Low Voltage |