× Auto Repair Pros Member Benefits TechHelp Knowledge Base Forums Resources My iATN Marketplace Chat Pricing About Us Join Industry Sponsors Video Members Only Repair Shops Auto Pro Careers Auto Pro Reviews
Join Now
International Automotive Technicians Network
1998 Buick Regal 25th Anniversary Edition 3.8L No Start
Posted to GM Driveability on 7/21/2004 14 Replies

Fuel pump will energize for 2 seconds and vehicle will start,after about 2 seconds power will be lost to the fuel pump and it will stall. The fuel pressure will come right back up to about 60lbs. I tried a cranksensor, ignition module and [...] does [...] help...

14 Replies Received (View Replies)

  Related Documents & Media  1998 Buick Regal 25th Anniversary Edition

 
Message Closed w/FIX

car Vehicle Data

1998 Buick Regal 25th Anniversary Edition

VIN 2G4WF5215W
Engine3.8 L / 6 cyl / GAS
Trans4-speed Automatic (Electronic)
DeliveryFI
EmissionsOBD-II Compliant
SymptomsNo Start
Message Closed w/FIX

car Vehicle Data

1998 Buick Regal 25th Anniversary Edition

VIN 2G4WF5215W
Engine3.8 L / 6 cyl / GAS
Trans4-speed Automatic (Electronic)
DeliveryFI
EmissionsOBD-II Compliant
SymptomsNo Start