1998 Mercury Mystique LS 2.5L MIL Lamp on
need help with this one. I have the bank 1 sensor 2 oxygen sensor keeps going bad. have been replacing with oe [...] sensor will work for about 1000 miles then it goes open. I have checked the harness all looks good there. When its replaced the oxygen works gr...
FIX posted 12/12/2006
![]()
iATN Members:
Login to view full TechHelp request Auto Repair Pros: Join iATN to read this TechHelp request Vehicle Owners: Find a nearby iATN member to repair your vehicle (View Replies)7 Replies Received(Hide Replies)7 Replies Received
|
Message Closed
|
VIN | 1MEFM66LOW |
Engine | 2.5 L / 6 cyl / GAS |
Trans | 4-speed Automatic (Electronic) |
Delivery | FI |
Emissions | OBD-II Compliant |
Symptoms | MIL Lamp On |
Occurs | Not Applicable |
Trouble Codes
P0136 | Heated Oxygen Sensor (Bank 1 Sensor 2) Heater Circuit Malfunction |
Message Closed
Vehicle Data
1998 Mercury Mystique LS
VIN | 1MEFM66LOW |
Engine | 2.5 L / 6 cyl / GAS |
Trans | 4-speed Automatic (Electronic) |
Delivery | FI |
Emissions | OBD-II Compliant |
Symptoms | MIL Lamp On |
Occurs | Not Applicable |
Trouble Codes
P0136 | Heated Oxygen Sensor (Bank 1 Sensor 2) Heater Circuit Malfunction |