1999 Ford Expedition Eddie Bauer 5.4L No Start, Cuts out, Stall, MIL Lamp on, ERRATIC GAUGE OPERAT
Posted to Ford Driveability on 6/23/2005 4 Replies

help we have a real brain burner here vehicle stall intermittently appx every 2-3 days here is what i know code p0161 returns constantly appears unrelated when acts up has no spark, no injector pulse and no communication with scanner does not lose battery volt...

4 Replies Received (View Replies)

  Related Documents & Media  1999 Ford Expedition Eddie Bauer

 
Message Closed w/Summary

car Vehicle Data

1999 Ford Expedition Eddie Bauer

VIN 1FMPU18L2X
Engine5.4 L / 8 cyl / GAS
Trans4-speed Automatic (Electronic)
DeliveryFI / MPI
EmissionsOBD-II Compliant
SymptomsNo Start, Cuts Out, Stall, MIL Lamp on, Erratic Gauge Operat
OccursIntermittently

Trouble Codes

P0161Heated Oxygen Sensor (Bank 2 Sensor 2) Heater Circuit Malfunction
Message Closed w/Summary

car Vehicle Data

1999 Ford Expedition Eddie Bauer

VIN 1FMPU18L2X
Engine5.4 L / 8 cyl / GAS
Trans4-speed Automatic (Electronic)
DeliveryFI / MPI
EmissionsOBD-II Compliant
SymptomsNo Start, Cuts Out, Stall, MIL Lamp on, Erratic Gauge Operat
OccursIntermittently

Trouble Codes

P0161Heated Oxygen Sensor (Bank 2 Sensor 2) Heater Circuit Malfunction