1994 Ford Ranger XL 3.0L Poor Idle Quality, Hesitation, Surge, Cuts out, Stall
died on road we have replaced coil cap rotor for code 211 test mass will run disconnected. installed new mass air flow sensor . get this truck starts and dies remove maf sensor from housing vehcal runs great but if i blow on sensor elements truck dies or stumb...
FIX posted 1/26/2005
![]()
iATN Members:
Login to view full TechHelp request Auto Repair Pros: Join iATN to read this TechHelp request Vehicle Owners: Find a nearby iATN member to repair your vehicle (View Replies)5 Replies Received(Hide Replies)5 Replies Received
|
Message Closed w/FIX
|
VIN | 1FTCR10URP |
Engine | 3.0 L / 6 cyl / GAS |
Trans | 4-speed Automatic |
Delivery | FI / sefi |
Emissions | fed |
Symptoms | Poor Idle Quality, Hesitation, Surge, Cuts Out, Stall |
Occurs | Always |
Message Closed w/FIX
Vehicle Data
1994 Ford Ranger XL
VIN | 1FTCR10URP |
Engine | 3.0 L / 6 cyl / GAS |
Trans | 4-speed Automatic |
Delivery | FI / sefi |
Emissions | fed |
Symptoms | Poor Idle Quality, Hesitation, Surge, Cuts Out, Stall |
Occurs | Always |