2001 Audi A6 Quattro 2.7L Cuts out, Stall, MIL Lamp on
when taking off from a dead stop vehicle sometimes spudders. It does it everytime when turning to the right, but only going forward, but never in reverse or turning to the left from a stop. cleared codes and set basic setting, and codes# 18041 and #16490 retur...
FIX posted 10/11/2005
iATN Members:
Login to view full TechHelp request Auto Repair Pros: Join iATN to read this TechHelp request Vehicle Owners: Find a nearby iATN member to repair your vehicle 3 Replies Received (View Replies)3 Replies Received (Hide Replies)
|
Message Closed
|
| VIN | WAUED54B81 |
| Engine | 2.7 L / 6 cyl / GAS |
| Trans | 6-speed Standard |
| Delivery | FI |
| Emissions | OBD-II Compliant |
| Symptoms | Cuts Out, Stall, MIL Lamp On |
| Occurs | On Accel, Turning, While Turning Right, Going Forward From a Stop |
| Misc. | 4Dr. Sedan, Quattro, Bi-Turbo |
Trouble Codes
| 16490 | manifold/ air pressure sensor g71/f96 failure - reoccuring |
| 16621 | boost pressure sensor g31 signal too low |
| 16730 | bank 2 cam sensor range/performance |
| 17746 | bank 1 cam senor g163 open/short intermittent |
| 18041 | throttle pedel position sensor 2 g185 signal too low -reoccuring |
Message Closed
Vehicle Data
2001 Audi A6 Quattro
| VIN | WAUED54B81 |
| Engine | 2.7 L / 6 cyl / GAS |
| Trans | 6-speed Standard |
| Delivery | FI |
| Emissions | OBD-II Compliant |
| Symptoms | Cuts Out, Stall, MIL Lamp On |
| Occurs | On Accel, Turning, While Turning Right, Going Forward From a Stop |
| Misc. | 4Dr. Sedan, Quattro, Bi-Turbo |
Trouble Codes
| 16490 | manifold/ air pressure sensor g71/f96 failure - reoccuring |
| 16621 | boost pressure sensor g31 signal too low |
| 16730 | bank 2 cam sensor range/performance |
| 17746 | bank 1 cam senor g163 open/short intermittent |
| 18041 | throttle pedel position sensor 2 g185 signal too low -reoccuring |