1998 Mercedes-Benz ML320 3.2L Misfire, MIL Lamp on, shuts off #2 % #6
over 2400RPM accumulates enough misfire faults to turn off cyls 2&6 will idle fine, unable to drive car long enough to perform sensor adaptation. came to us from another shop, they put coils, wires, plugs and a CKP on it to no avail. Vacuum is aprox 15-17 [......
FIX posted 8/13/2009
![]()
iATN Members:
Login to view full TechHelp request Auto Repair Pros: Join iATN to read this TechHelp request Vehicle Owners: Find a nearby iATN member to repair your vehicle (View Replies)12 Replies Received(Hide Replies)12 Replies Received
|
Message Closed w/FIX
|
VIN | WDBKK47F2W |
Engine | 3.2 L / 6 cyl / GAS |
Trans | 5-speed Automatic (Electronic) |
Delivery | FI / ME2.0 |
Emissions | OBD-II Compliant |
Symptoms | Misfire, MIL Lamp on, Shuts Off #2 % #6 |
Occurs | Over 2400 RPM |
Trouble Codes
P0300 | Multiple Misfire Detected |
P0302 | Cylinder 2 Misfire Detected |
P0306 | Cylinder 6 Misfire Detected |
Message Closed w/FIX
Vehicle Data
1998 Mercedes-Benz ML320
VIN | WDBKK47F2W |
Engine | 3.2 L / 6 cyl / GAS |
Trans | 5-speed Automatic (Electronic) |
Delivery | FI / ME2.0 |
Emissions | OBD-II Compliant |
Symptoms | Misfire, MIL Lamp on, Shuts Off #2 % #6 |
Occurs | Over 2400 RPM |
Trouble Codes
P0300 | Multiple Misfire Detected |
P0302 | Cylinder 2 Misfire Detected |
P0306 | Cylinder 6 Misfire Detected |