1997 Audi A6 2.8L Readiness Monitors
this 97-a6 was brought to us for not passing inspection due to readiness monitors. we had codes for a ho2s bank 2 sensor 1 in diagnosing this code we found that the brand new ho2s that was installed from somebody else the connector was plugged into the egr tem...
FIX posted 6/22/2009
iATN Members:
Login to view full TechHelp request Auto Repair Pros: Join iATN to read this TechHelp request Vehicle Owners: Find a nearby iATN member to repair your vehicle 9 Replies Received (View Replies)9 Replies Received (Hide Replies)
|
Message Closed w/FIX
|
| VIN | WAUGA84A7V |
| Engine | 2.8 L / 6 cyl / GAS |
| Trans | 4-speed Automatic (Electronic) |
| Delivery | FI |
| Emissions | OBD-II Compliant |
| Symptoms | Readiness Monitors |
| Occurs | Always |
Trouble Codes
| P0155 | Heated Oxygen Sensor (Bank 2 Sensor 1) Heater Circuit Malfunction |
| P1606 | Rough Road Sensor Circuit Not Valid |
Message Closed w/FIX
Vehicle Data
1997 Audi A6
| VIN | WAUGA84A7V |
| Engine | 2.8 L / 6 cyl / GAS |
| Trans | 4-speed Automatic (Electronic) |
| Delivery | FI |
| Emissions | OBD-II Compliant |
| Symptoms | Readiness Monitors |
| Occurs | Always |
Trouble Codes
| P0155 | Heated Oxygen Sensor (Bank 2 Sensor 1) Heater Circuit Malfunction |
| P1606 | Rough Road Sensor Circuit Not Valid |