1999 Audi A6 2.8L MIL Lamp on
Audi techs i hope you have some insight. This car came in for a ck engine light, found 14 codes in all most of which refer to a short to ground. Customer has been driving for a month with no drivability problems. found fuse # 29 ecm 30 amp blown, Replace fuse ...
FIX posted 5/1/2009
![]()
iATN Members:
Login to view full TechHelp request Auto Repair Pros: Join iATN to read this TechHelp request Vehicle Owners: Find a nearby iATN member to repair your vehicle (View Replies)12 Replies Received(Hide Replies)12 Replies Received
|
Message Closed
|
VIN | WAUB124B6X |
Engine | 2.8 L / 6 cyl / GAS |
Trans | 5-speed Automatic (Electronic) |
Delivery | FI / multiport |
Emissions | OBD-II Compliant |
Symptoms | MIL Lamp On |
Occurs | Always |
Trouble Codes
P1196 | Heated Oxygen Sensor (Bank 2 Sensor 1) Slow In The Catalyst Monitor Test |
P1421 | Cold Start Control |
P1425 | EVAP Purge Solenoid Circuit Low Input |
P1435 | Charge/Discharge Balance Function |
P1472 | evap emm control lpp short to b |
Message Closed
Vehicle Data
1999 Audi A6
VIN | WAUB124B6X |
Engine | 2.8 L / 6 cyl / GAS |
Trans | 5-speed Automatic (Electronic) |
Delivery | FI / multiport |
Emissions | OBD-II Compliant |
Symptoms | MIL Lamp On |
Occurs | Always |
Trouble Codes
P1196 | Heated Oxygen Sensor (Bank 2 Sensor 1) Slow In The Catalyst Monitor Test |
P1421 | Cold Start Control |
P1425 | EVAP Purge Solenoid Circuit Low Input |
P1435 | Charge/Discharge Balance Function |
P1472 | evap emm control lpp short to b |