2000 Volvo S40 1.9L MIL Lamp on
We looked everything over. Exhaust system is tight. Smoke tested intake track for vacum leaks. Scope test on upstream O2 in shop shows switching rate of 6-7 times,range is 200-850 mv in 5 seconds at 2000 rpm. Down stream is 2 times in 5 seconds with a range of...
FIX posted 7/21/2008
![]()
iATN Members:
Login to view full TechHelp request Auto Repair Pros: Join iATN to read this TechHelp request Vehicle Owners: Find a nearby iATN member to repair your vehicle (View Replies)8 Replies Received(Hide Replies)8 Replies Received
|
Message Closed w/FIX
|
VIN | YV1V529591 |
Engine | 1.9 L / 4 cyl / GAS |
Trans | 4-speed Automatic (Electronic) |
Delivery | FI |
Emissions | OBD-II Compliant |
Symptoms | MIL Lamp On |
Occurs | Always |
Trouble Codes
P0133 | Heated Oxygen Sensor (Bank 1 Sensor 1) Slow Response |
Message Closed w/FIX
Vehicle Data
2000 Volvo S40
VIN | YV1V529591 |
Engine | 1.9 L / 4 cyl / GAS |
Trans | 4-speed Automatic (Electronic) |
Delivery | FI |
Emissions | OBD-II Compliant |
Symptoms | MIL Lamp On |
Occurs | Always |
Trouble Codes
P0133 | Heated Oxygen Sensor (Bank 1 Sensor 1) Slow Response |