2000 Audi A6 Quattro 2.8L MIL Lamp on
this car had a reoccuring po411 low flow secondary air injection. did all above now p1423 low flow b1 . have noticed maf is glitchy at idle . cuold this be the cuase. from all the info i see o2 sensors are the monitor . any other ideas o2 sensors seem fine.
Summary posted 6/18/2008
![]()
iATN Members:
Login to view full TechHelp request Auto Repair Pros: Join iATN to read this TechHelp request Vehicle Owners: Find a nearby iATN member to repair your vehicle (View Replies)6 Replies Received(Hide Replies)6 Replies Received
|
Message Closed w/Summary
|
VIN | WAUEH24B8Y |
Engine | 2.8 L / 6 cyl / GAS |
Trans | 4-speed Automatic (Electronic) |
Delivery | FI |
Emissions | OBD-II Compliant |
Symptoms | MIL Lamp On |
Occurs | Intermittently |
Trouble Codes
P0411 | Too Much Or Too Little Pulsed Air Injection |
P1423 | Fuel Tank Large Leak |
Message Closed w/Summary
Vehicle Data
2000 Audi A6 Quattro
VIN | WAUEH24B8Y |
Engine | 2.8 L / 6 cyl / GAS |
Trans | 4-speed Automatic (Electronic) |
Delivery | FI |
Emissions | OBD-II Compliant |
Symptoms | MIL Lamp On |
Occurs | Intermittently |
Trouble Codes
P0411 | Too Much Or Too Little Pulsed Air Injection |
P1423 | Fuel Tank Large Leak |