2000 Audi A6 Quattro 2.8L MIL Lamp on
this car had a reoccuring po411 low flow secondary air injection. did all above now p1423 low flow b1 . have noticed maf is glitchy at idle . cuold this be the cuase. from all the info i see o2 sensors are the monitor . any other ideas o2 sensors seem fine.
Summary posted 6/18/2008
iATN Members:
Login to view full TechHelp request Auto Repair Pros: Join iATN to read this TechHelp request Vehicle Owners: Find a nearby iATN member to repair your vehicle 6 Replies Received (View Replies)6 Replies Received (Hide Replies)
|
Message Closed w/Summary
|
| VIN | WAUEH24B8Y |
| Engine | 2.8 L / 6 cyl / GAS |
| Trans | 4-speed Automatic (Electronic) |
| Delivery | FI |
| Emissions | OBD-II Compliant |
| Symptoms | MIL Lamp On |
| Occurs | Intermittently |
Trouble Codes
| P0411 | Too Much Or Too Little Pulsed Air Injection |
| P1423 | Fuel Tank Large Leak |
Message Closed w/Summary
Vehicle Data
2000 Audi A6 Quattro
| VIN | WAUEH24B8Y |
| Engine | 2.8 L / 6 cyl / GAS |
| Trans | 4-speed Automatic (Electronic) |
| Delivery | FI |
| Emissions | OBD-II Compliant |
| Symptoms | MIL Lamp On |
| Occurs | Intermittently |
Trouble Codes
| P0411 | Too Much Or Too Little Pulsed Air Injection |
| P1423 | Fuel Tank Large Leak |
6 Replies Received
6 Replies Received
Related Documents & Media