2003 Audi A6 Quattro 4.2L Excessive Emissions, Misfire, MIL Lamp on
Customer previously had the Audi to another shop. They installed 8 new coils and an air mass meter,-genuine Audi parts. The Audi will idle steady and not misfire. While watching the misfire counter on the vag scanner you can see misfires in all 8 cylinders whe...
FIX posted 11/13/2007
iATN Members:
Login to view full TechHelp request Auto Repair Pros: Join iATN to read this TechHelp request Vehicle Owners: Find a nearby iATN member to repair your vehicle 10 Replies Received (View Replies)10 Replies Received (Hide Replies)
|
Message Closed w/FIX
|
| VIN | WAUML64B13 |
| Engine | 4.2 L / 8 cyl / GAS |
| Trans | 5-speed Automatic (Electronic) |
| Delivery | FI |
| Emissions | OBD-II Compliant |
| Symptoms | Excessive Emissions, Misfire, MIL Lamp On |
| Occurs | On Accel |
Trouble Codes
| P0300 | Multiple Misfire Detected |
| P0301 | Cylinder 1 Misfire Detected |
| P0302 | Cylinder 2 Misfire Detected |
| P0303 | Cylinder 3 Misfire Detected |
| P0305 | Cylinder 5 Misfire Detected |
| P0307 | Cylinder 7 Misfire Detected |
Message Closed w/FIX
Vehicle Data
2003 Audi A6 Quattro
| VIN | WAUML64B13 |
| Engine | 4.2 L / 8 cyl / GAS |
| Trans | 5-speed Automatic (Electronic) |
| Delivery | FI |
| Emissions | OBD-II Compliant |
| Symptoms | Excessive Emissions, Misfire, MIL Lamp On |
| Occurs | On Accel |
Trouble Codes
| P0300 | Multiple Misfire Detected |
| P0301 | Cylinder 1 Misfire Detected |
| P0302 | Cylinder 2 Misfire Detected |
| P0303 | Cylinder 3 Misfire Detected |
| P0305 | Cylinder 5 Misfire Detected |
| P0307 | Cylinder 7 Misfire Detected |