	 1999 Mercedes-Benz CLK320 3.2L MIL Lamp on 
		
		Sets code po130 . replaced O2 sensor code rturned after 2 days of driving. checked voltage on all O2 sensors bank 1 sensor 1 .50 bank 1 sens 2 .48, bank 2 sens 1 up and down .72 at cold start up varies between .16 and .77 Only have obdII scan on OTC scanner no... 
                        
                            Summary posted 4/21/2007
                             
                 
                            
                    iATN Members:  
        Login to view full TechHelp request Auto Repair Pros: Join iATN to read this TechHelp request Vehicle Owners: Find a nearby iATN member to repair your vehicle 16 Replies Received (View Replies)16 Replies Received (Hide Replies)
       | 
		  
		      
         Message Closed w/Summary 
	   
	   
	   
	    | 
| VIN | WDBLK65G1X | 
| Engine | 3.2 L / 6 cyl / GAS | 
| Trans | 5-speed Automatic (Electronic) | 
| Delivery | FI | 
| Emissions | OBD-II Compliant | 
| Symptoms | MIL Lamp On | 
| Occurs | Intermittently | 
| Misc. | Convertable | 
Trouble Codes
| P0130 | Heated Oxygen Sensor (Bank 1 Sensor 1) Circuit Malfunction | 
Message Closed w/Summary
            
            
 Vehicle Data
                1999 Mercedes-Benz CLK320
| VIN | WDBLK65G1X | 
| Engine | 3.2 L / 6 cyl / GAS | 
| Trans | 5-speed Automatic (Electronic) | 
| Delivery | FI | 
| Emissions | OBD-II Compliant | 
| Symptoms | MIL Lamp On | 
| Occurs | Intermittently | 
| Misc. | Convertable | 
Trouble Codes
| P0130 | Heated Oxygen Sensor (Bank 1 Sensor 1) Circuit Malfunction | 
                            