Original pump actually broke internally. Never seen this. New pump installed, no activation. Check for power and ground-still good. Ran 12 volts directly to pump and it works. Back probe plug at pump while plugged in-power flashes on then gone. Trace probl...
FIX posted 7/1/2021
iATN Members:
Login to view full TechHelp request Auto Repair Pros: Join iATN to read this TechHelp request Vehicle Owners: Find a nearby iATN member to repair your vehicle 7 Replies Received (View Replies)7 Replies Received (Hide Replies)
|
Message Closed w/FIX
|
| VIN | 1J8HG48K47 |
| Engine | 3.7 L / 6 cyl / GAS |
| Trans | 5-speed Automatic (Electronic) |
| Delivery | Fuel Injection |
| Emissions | OBD-II Compliant |
| Symptoms | No Start |
| Occurs | After a Hot Soak |
Message Closed w/FIX
Vehicle Data
2007 Jeep Commander
| VIN | 1J8HG48K47 |
| Engine | 3.7 L / 6 cyl / GAS |
| Trans | 5-speed Automatic (Electronic) |
| Delivery | Fuel Injection |
| Emissions | OBD-II Compliant |
| Symptoms | No Start |
| Occurs | After a Hot Soak |