2001 Infiniti QX4 3.5L MIL Lamp on
Vehicle was brought to other shop for emissions p0301 and p1320. Replaced coil on cyl 1, no misfire, engine runs smooth, p1320 comes back immediately after clearing. Shop replaced both crank sensors. Alldata info stated that logic of code is when primary ignit...
FIX posted 1/23/2014
![]()
iATN Members:
Login to view full TechHelp request Auto Repair Pros: Join iATN to read this TechHelp request Vehicle Owners: Find a nearby iATN member to repair your vehicle (View Replies)8 Replies Received(Hide Replies)8 Replies Received
|
Message Closed w/FIX
|
VIN | JNRDR07Y31 |
Engine | 3.5 L / 6 cyl / GAS |
Trans | 4-speed Automatic (Electronic) |
Delivery | Fuel Injection |
Emissions | OBD-II Compliant |
Symptoms | MIL Lamp On |
Occurs | Always |
Trouble Codes
P1320 | ICM 4X Reference Circuit No Pulses (Intermittent) |
Message Closed w/FIX
Vehicle Data
2001 Infiniti QX4
VIN | JNRDR07Y31 |
Engine | 3.5 L / 6 cyl / GAS |
Trans | 4-speed Automatic (Electronic) |
Delivery | Fuel Injection |
Emissions | OBD-II Compliant |
Symptoms | MIL Lamp On |
Occurs | Always |
Trouble Codes
P1320 | ICM 4X Reference Circuit No Pulses (Intermittent) |