2007 Honda Element EX 2.4L MIL Lamp on
The vent valve was shorted. We replaced same and the canister. Both valves and the pressure sensor work when tested with scan tool and all hoses are clear. Code comes back on second road test. Any thoughts?
FIX posted 9/20/2012
iATN Members:
Login to view full TechHelp request Auto Repair Pros: Join iATN to read this TechHelp request Vehicle Owners: Find a nearby iATN member to repair your vehicle 6 Replies Received (View Replies)6 Replies Received (Hide Replies)
|
Message Closed w/FIX
|
| VIN | 5J6YH28717 |
| Engine | 2.4 L / 4 cyl / GAS |
| Trans | 5-speed Automatic (Electronic) |
| Delivery | Fuel Injection |
| Emissions | OBD-II Compliant |
| Symptoms | MIL Lamp On |
| Occurs | Always |
Trouble Codes
| P2422 | EVAP Canister Vent Shut Valve Close Malfunction |
Message Closed w/FIX
Vehicle Data
2007 Honda Element EX
| VIN | 5J6YH28717 |
| Engine | 2.4 L / 4 cyl / GAS |
| Trans | 5-speed Automatic (Electronic) |
| Delivery | Fuel Injection |
| Emissions | OBD-II Compliant |
| Symptoms | MIL Lamp On |
| Occurs | Always |
Trouble Codes
| P2422 | EVAP Canister Vent Shut Valve Close Malfunction |