2006 Hyundai Tucson GL 2.0L MIL Lamp on
Removed OCV and bench test. Valve operates. Scoped both cam and crank sensors. Patterns appear to be normal. Checked timing belt. All marks line-up. Ingition timing at idle on scanner says [...]. As rpm's are increased timing decreases.
FIX posted 7/23/2011
![]()
iATN Members:
Login to view full TechHelp request Auto Repair Pros: Join iATN to read this TechHelp request Vehicle Owners: Find a nearby iATN member to repair your vehicle (View Replies)3 Replies Received(Hide Replies)3 Replies Received
|
Message Closed
|
VIN | KM8J12B36U |
Engine | 2.0 L / 4 cyl / GAS |
Trans | 4-speed Automatic (Electronic) |
Delivery | Fuel Injection |
Emissions | OBD-II Compliant |
Symptoms | MIL Lamp On |
Occurs | Always |
Trouble Codes
P0016 | Crankshaft/Camshaft Timing Misalignment |
Message Closed
Vehicle Data
2006 Hyundai Tucson GL
VIN | KM8J12B36U |
Engine | 2.0 L / 4 cyl / GAS |
Trans | 4-speed Automatic (Electronic) |
Delivery | Fuel Injection |
Emissions | OBD-II Compliant |
Symptoms | MIL Lamp On |
Occurs | Always |
Trouble Codes
P0016 | Crankshaft/Camshaft Timing Misalignment |