1999 Nissan Sentra XE 1.6L No Start
installed used engine afterwards cant get fire no power to 2 wire conecter going to coil but when add power still will not start alldata did not give good location on connecters relating to this wire all i could find was the main harness and the dist connector...
FIX posted 3/19/2008
iATN Members:
Login to view full TechHelp request Auto Repair Pros: Join iATN to read this TechHelp request Vehicle Owners: Find a nearby iATN member to repair your vehicle 4 Replies Received (View Replies)4 Replies Received (Hide Replies)
|
Message Closed w/FIX
|
| VIN | 3N1AB4AD3X |
| Engine | 1.6 L / 4 cyl / GAS |
| Trans | 4-speed Automatic |
| Delivery | FI |
| Emissions | OBD-II Compliant |
| Symptoms | No Start |
| Occurs | Always |
Trouble Codes
| P1320 | ICM 4X Reference Circuit No Pulses (Intermittent) |
Message Closed w/FIX
Vehicle Data
1999 Nissan Sentra XE
| VIN | 3N1AB4AD3X |
| Engine | 1.6 L / 4 cyl / GAS |
| Trans | 4-speed Automatic |
| Delivery | FI |
| Emissions | OBD-II Compliant |
| Symptoms | No Start |
| Occurs | Always |
Trouble Codes
| P1320 | ICM 4X Reference Circuit No Pulses (Intermittent) |