1999 Honda Odyssey LX 3.5L MIL Lamp on
Vehicle has CEL on with code P0401 insufficient EGR flow. Found passage restricted in bottom of intake manifold. Cleaned passages. Road tested, monitor completed and passed but would not turn off the CEL. Our question is will the computer turn off the CEL or d...
FIX posted 1/8/2004
iATN Members:
Login to view full TechHelp request Auto Repair Pros: Join iATN to read this TechHelp request Vehicle Owners: Find a nearby iATN member to repair your vehicle 12 Replies Received (View Replies)12 Replies Received (Hide Replies)
|
Message Closed w/FIX
|
| VIN | 2HKRL1852X |
| Engine | 3.5 L / 6 cyl / GAS |
| Trans | 4-speed Automatic (Electronic) |
| Delivery | FI / SEFI |
| Emissions | OBD-II Compliant |
| Symptoms | MIL Lamp On |
| Occurs | Always |
Trouble Codes
| P0401 | EGR System Insufficient Flow Detected |
Message Closed w/FIX
Vehicle Data
1999 Honda Odyssey LX
| VIN | 2HKRL1852X |
| Engine | 3.5 L / 6 cyl / GAS |
| Trans | 4-speed Automatic (Electronic) |
| Delivery | FI / SEFI |
| Emissions | OBD-II Compliant |
| Symptoms | MIL Lamp On |
| Occurs | Always |
Trouble Codes
| P0401 | EGR System Insufficient Flow Detected |