× Auto Repair Pros Member Benefits TechHelp Knowledge Base Forums Resources My iATN Marketplace Chat Pricing About Us Join Industry Sponsors Video Members Only Repair Shops Auto Pro Careers Auto Pro Reviews
Join Now
International Automotive Technicians Network

P1167 Diagnostic Trouble Code Discussion for May 2016

Heated Oxygen Sensor (Bank 2 Sensor 2) Maximum Voltage Monitoring


Note: This is a professional automotive technician's resource.
Vehicle Owners: If you are seeking an automotive repair professional to service your vehicle, visit the iATN Repair Shop Finder.

Trouble Ticket Help Requests for DTC P1167
Help Request Posted
2002 Kia Optima SE 2.7L Hesitation, MIL Lamp on, Poor Performance VIN: KNAGD12842
P1167: Oxygen Sensor System Lambda Bank Controller At Limit (Bank 2). We have this Kia that came in with MIL on and a complaint of sluggish acceleration. From a stop the car with hesitate and accelerate very slowly then suddenly just kick in and accelerate good. Monitored the O2 sensors. Bank 1 is fluctuating between very low ...
May 16, 2016
2002 Kia Optima SE 2.7L Hesitation, MIL Lamp on, Poor Performance VIN: KNAGD12842
P1167: Oxygen Sensor System Lambda Bank Controller At Limit (Bank 2). We have this Kia that came in with MIL on and a complaint of sluggish acceleration. From a stop the car with hesitate and accelerate very slowly then suddenly just kick in and accelerate good. Monitored the O2 sensors. Bank 1 is fluctuating between very low ...
May 18, 2016